* Version 1.0.18 PNA4500 Date : 2017-01-18 Info : - Assistant page for Power Meter - TCP protocol 0.02 * Version 1.0.17 PNA4500 Date : 2017-01-13 Info : - Assistant page * Version 1.0.16 PNA4500 Date : 2017-01-09 Info : - DLL Tetra improvements * Version 1.0.15 PNA4500 Date : 2016-12-01 Info : - TETRA : improvemnts Tetra module - PM: improvemnts connection PM - ASSISTANT: added starting page and improvements - New DLL for TETRA * Version 1.0.14 PNA4500 Date : 2016-11-10 Info : - TETRA : added tertra module * Version 1.0.13 PNA4500 Date : 2016-09-01 Info : - PM: added on Trace menu "Offset Setting" and "Relative Setting" - PM: addedon Setup menu "Power Setting" to view Min, AVG and Max Power - VNA: added Assistant (active using encoder button) - VNA: added exe Vector Config e Vector Assistant on main setup * Version 1.0.12 PNA4500 Date : 2016-07-28 Info : - Add TCP server on 1893 port: TCP Protocol 0.1 * Version 1.0.11 PNA4500 Date : 2016-07-08 Info : - PM: added USB Power Meter (selected from PM- Setup menu) - PM: added Marker menu - PM: added mode work (Continue, single, Normal) only for USB PM - PM: added Sampling setting for USB PM, add Trigger setting for mode Single and Normal - VNA - FILE : view report improvements - VNA/DTF - FILE: keyboard is opened to save printscreen and trace - VNA - FILE : added 'Load File' button for .s1p files: the trace is loaded on Refernce data. Number of SweepPoint and Freq Start/Stop is forced to the value stored in the file - GPS Antenna : start hw with GPS antenna selected make the hardkey active * Version 1.0.10 PNA4500 Date : 2016-06-01 Info : - VNA: Added Default Preset on File Menu (Default Preset automatically created) - VNA: Calibration in association with Load preset or Start/stop modify improvements * Version 1.0.9 PNA4500 Date : 2016-05-03 Info : - Server DLL version 52 - VNA: bug on smith char marker * Version 1.0.8 PNA4500 Date : 2016-05-03 Info : - VNA - Scale : error label scale - VNA - smith : mk improvements (enabled mk 1,2 3,4) - VNA Services - load File improvements * Version 1.0.7 PNA4500 Date : 2016-05-02 Info : - VNA - Trace : smith char improvements (maker string) - SWR , Smith char disaled fpr S21 * Version 1.0.6 PNA4500 Date : 2016-04-28 Info : - if On Screen Keyboard disabled => the icon is not visible - On screen Keyboard active in "Save As" into Report - Marker: 'on/off button' for a selected marker put the marker off - DTF-File-Save-Trace: now saves a trace in s1p format. Added into trace file Dielectric value. - DTF - Load File: decode the Dielectric value saved and if it is different from the actual Dielecric ask you to change it. - DTF - Load File: new value for Dieletric Value or Range in Load file mode set "DTF Mode " to Auto mode - DTF - File -Save : added Operator and Site info. This info are saved into Report and into Trace - DTF - Setup -Calibration: when you press Done sw go to setup menu and show DTF - DTF - File-Preset -Load: added Delete preset - VNA - Setup : new value of Filter BW or Point set Sweep Time to minimun value - VNA - Marker Coupled improvements. Dieletric.xml file: put this file into \Documents\PROTECS\PNA4500 directory to show a Cable list for different Dieletricum. You can add new cables in the file: change the number of cable into tab and then add at the end of the file new tag with the Cable Name and Value. * Version 1.0.4 PNA4500 Date : 2016-04-21 Info : - new logo Protecs - added button "Keyboard on screen" Enable on Setup menu and added keyboard image on form - S11/SWR scale : now 0.2 0.5 /div - Report File SWR mode: SWR values shown - New Marker Menu (added Delta, Min/MAx and Track functions) - Report DTF: added distance - UI refresh eliminated - Added "Span min" on VNA mode (Start menu) as similar CW function - Calibration only with S11, if Format is SWR revert to s11 for calibration